Additional sections will be published as they are completed.
1. Unpacking and Contents
Before starting installation, unpack your Amanzi Lawula Automated Tank Controller and check that all the following items are included.
Ultrasonic sensor — 3 m cable with 4-pin plug.
Control box — 2 m 220 V power cable with 15 A plug.
24 V AC solenoid valve — 3 m cable with 2-pin plug.
Two mounting screws and spacers.
One paper drilling template for positioning the sensor mounting holes in the tank.
Important: The paper template is used to mark the pilot-hole centres, 34 mm apart. The final sensor openings are 17 mm diameter (maximum 20 mm), as described in the sensor installation instructions. Do not treat the illustration as a full-size drilling template.
If anything is missing or damaged, contact your supplier before installation.
2. Installing the Solenoid Valve
The following illustrated guide shows how to install the Amanzi Lawula solenoid valve on the incoming water supply to the tank.
Important: Follow the moulded flow-direction arrow near the valve's threaded connection. Keep the solenoid disconnected from the controller during plumbing work. Connect its 2-pin plug only after installation, with the controller power switched off. Test the valve after completing controller setup.
3. Controller Indicator Lights & Pairing Button
The Amanzi Lawula controller has three LED indicators
and one pairing button located on the main circuit board.
3.1 Green LED — Controller Operation
Status
Meaning
Flashing every second
Controller operating normally
OFF
No power or controller fault
During normal operation, the green LED flashes continuously
at one-second intervals.
3.2 Red LED — Pump Operation & Sensor Fault
Status
Meaning
Flashing
Water level sensor fault
Constantly ON
Pump relay activated — tank filling
OFF
Relay inactive, no sensor fault indicated
Automatic Sensor Fault Protection
If the water level sensor develops a fault at any time,
the controller automatically switches the pump relay OFF.
The red LED flashes to indicate the fault.
Tank filling stops to prevent possible overfilling.
This protection applies in both ON and AUTO operating modes.
3.3 Blue LED — Network & Pairing
Status
Meaning
Flashing
Pairing mode active
Constantly ON
Network connected
OFF
No network connection
3.4 Pairing Button
First-Time Power-Up
A new controller automatically enters pairing mode
when powered ON for the first time.
Switch ON the controller.
The blue LED begins flashing automatically.
Open the Amanzi Lawula Android application.
Complete pairing within five minutes.
Once pairing is successful, the blue LED remains
constantly illuminated when the controller is connected
to the network.
If Pairing Fails or Times Out
If pairing is not completed within five minutes,
the controller automatically exits pairing mode.
Pairing can be restarted using either method:
Press and hold the pairing button for five seconds until the blue LED flashes.
Alternatively, switch the controller OFF and ON again.
Important:
Restarting pairing by switching the power OFF and ON
only works before the controller has been successfully
paired for the first time.
Previously Paired Controllers
Once a controller has been paired, it will not
automatically enter pairing mode after restarting.
To activate pairing mode again, press and hold
the pairing button for five seconds until
the blue LED begins flashing.
Pairing mode automatically expires after five minutes.
4. Controller External Connections
The controller has three external connections,
identified from right to left.
4.1 Power Supply — Right Connection
The controller is supplied with a power cable
fitted with a standard 15A plug for connection
to a 220V AC power supply.
4.2 Water Level Sensor — Middle Connection
The middle connector has four pins and a white
alignment dot.
Switch OFF the controller.
Align the white identification dots.
Carefully insert the sensor plug.
Secure the locking collar.
Never force the sensor connector.
Incorrect alignment may bend or damage the pins.
4.3 Filler Valve / Relay Output — Left Connection
Specification
Value
Output voltage
24V AC
Maximum current
1A
Connector
2-pin
Polarity
Non-polarised
The output supplies switched 24V AC to the filler valve
or an external relay.
IMPORTANT — NOT A DRY CONTACT
This output supplies 24V AC when activated.
It must never be used as a volt-free relay contact.
Any external relay connected to this output must
have a 24V AC coil, with a current draw not exceeding
the controller's 1A output rating.
Always align the white identification dots before
connecting the two-pin plug.
5. Mounting the Water Level Sensor
6. Mounting the Control Box
7. Initial Wi-Fi Setup — Android App or Web Browser
Before continuing, switch on the Amanzi Lawula controller and allow it to start. A flashing blue indicator LED shows that the controller is awaiting initial Wi-Fi setup. Choose either method below; you do not need to complete both.
7.1 Method A — Android App
Download and install
On your Android phone, scan the QR code or use the direct download link to obtain the Amanzi Lawula app.
Follow the Android installation prompts. If Android requests permission to install from this source, allow it only if you trust the source.
Open the Amanzi Lawula app. Allow Bluetooth or nearby-device permissions if requested.
Find the controller and configure Wi-Fi
In the app, select Find Controller.
Wait for the available controllers to appear, then select your controller from the list.
Select the option to search for Wi-Fi networks.
Choose your home or business Wi-Fi network and carefully enter its password. Wi-Fi passwords are case-sensitive.
Select Test and wait for confirmation that the connection works.
If the test succeeds, select Save.
Wait until the blue LED stops flashing and remains steadily illuminated.
Write down the controller's full serial number shown in the app. You will need its last five digits to identify the controller.
Android app setup complete. Continue to Section 8 — Configuration.
7.2 Method B — Without the App (Android, Apple iPhone or Other Wi-Fi Device)
Use this method to commission the controller directly through your phone's web browser. No app installation is required.
Step 1 — Power on the controller
Switch on the controller and allow it to start.
Check that the blue LED is flashing.
Step 2 — Open your phone's Wi-Fi settings
Android: Open Settings → Connections → Wi-Fi, or Settings → Network & Internet → Internet, depending on the phone.
Apple iPhone: Open Settings → Wi-Fi.
Make sure Wi-Fi is switched on.
Step 3 — Connect to Tank-Setup
From the available Wi-Fi networks, select Tank-Setup.
Enter the password: tanksetup.
Tap Connect (Android) or Join (iPhone).
Note: Your phone may warn that Tank-Setup has no internet access. This is normal. Remain connected to Tank-Setup.
Step 4 — Open the controller's web interface
Open Chrome, Safari or another web browser.
Enter http://192.168.4.1 in the browser address bar.
When the Amanzi Lawula interface appears, select Network.
Step 5 — Select your Wi-Fi network
Select Search for Wi-Fi Networks.
Select your home or business Wi-Fi network.
Enter the Wi-Fi password accurately, including uppercase/lowercase letters and symbols.
Select Test and Save.
Wait for the controller to connect. The blue LED should stop flashing and remain steadily illuminated.
Step 6 — Reconnect your phone to your normal Wi-Fi
Return to the phone's Wi-Fi settings.
Reconnect to your home or business Wi-Fi network.
Ensure the phone and controller are on the same local network.
Browser setup complete. Continue to Section 8 — Configuration.
8. Controller Configuration
Step 1 — Open the Controller Dashboard
On your smartphone, tablet or computer, connect to the same local Wi-Fi network as your Amanzi Lawula controller. Open a web browser and enter:
http://lawula-XXXXX.local
Replace XXXXX with the last five digits of the serial number printed on your controller. For example, serial AES-2610-00002 uses http://lawula-00002.local.
The controller dashboard should appear, as shown below.
Step 2 — Check the Dashboard
Check that the dashboard opens and no error messages are displayed.
Check that the tank level indicator displays a reading. It may show water in the tank or 0% if the tank is empty.
Do not worry if the indicated level is inaccurate at this stage: the tank dimensions and sensor position have not yet been configured.
Step 3 — Configure Your Tank
From the dashboard, select Tank Settings. The configuration screen will appear:
Tank Name
Enter a name that identifies this tank, such as House Water Tank, Irrigation Tank or Backup Water Tank.
Tank Capacity (L)
Enter the volume of water, in litres, held by the tank at your chosen maximum operating water level.
Full Water Height (mm)
Measure the vertical distance from the bottom of the tank to the water surface at the chosen 100% full level. Enter this height in millimetres.
Sensor Above Full Level (mm)
Measure the vertical gap between the 100% full water level and the bottom faces of the ultrasonic sensor's transducers (the sensor buttons). Enter this measurement in millimetres.
Typical guide: On some JoJo tank installations this gap is approximately 150 mm. Your installation may differ. Measure your actual gap; do not assume 150 mm.
Automatic Fill
Start Filling At (%): Enter the minimum tank level at which automatic filling should begin.
Stop Filling At (%): Enter the level at which automatic filling should stop.
The Stop Filling percentage must be greater than the Start Filling percentage.
Sensor Calibration
The 100% Full Reading and 0% Empty Reading are calculated from the dimensions you enter. They represent the expected sensor-to-water distances at those levels.
Save Your Configuration
Check the tank name, capacity, measurements and filling percentages.
Select Save Tank Configuration.
Return to Dashboard to view the updated tank information.
Tank configuration saved. The controller is now configured for your tank's dimensions and preferred automatic filling levels.
Additional Manual Sections
The remaining installation, Android application,
network configuration and cloud subscription
instructions will be added as they are completed.